PRODUCTS CENTER

Current location:HOME - Transformer products - SC (B) 13 dry type transformer
  • w88

SC (B) 13 dry type transformer

Low loss: The product no-load loss is more than 30% lower than that of SCB10 type, and the load loss is more than 10% lower than that of SCB11 type. It has excellent energy saving effect, economical operation and maintenance-free.Low noise: …
Free access to information Click online consultation

Hotline

400-110-2022

60 seconds of manual response

Give technical advice within 30 minutes

24-hour free design

product description

Model meaning


w88


Features


Low loss: The product no-load loss is more than 30% lower than that of SCB10, and all losses are lower than SCB13 dry-type transformer. It has excellent energy saving effect, economical operation and maintenance-free.

Low noise: The noise level of the product is 10-15 dB lower than the current professional standard JB/T10088-2016 "6-220KV transformer sound level".

Low partial discharge: The resin mixture adopts advanced foreign stirring method and vacuum film degassing technology to make the mixture evenly stirred, completely eliminating the bubbles in the mixture. The product has only a very low partial discharge and can be controlled below 5PC. Both the high and low voltage coils are cast under vacuum and pressure, so that the resin insulation has both full encapsulation and interlayer leaching. The cast body has a dense solidified structure, which is flame retardant, explosion-proof and does not pollute the environment.

The insulating material such as glass fiber wound around the coil has self-extinguishing characteristics, and does not generate an arc due to a short circuit, and the resin does not generate toxic and harmful gas under high heat.

High mechanical strength: The resin with filler makes the difference of expansion coefficient in the casting body small, the curing shrinkage rate is small, the internal stress is small, and the hardness of the cured product is high. It is placed in the epoxy resin encapsulation layer on the inner and outer surfaces of the high and low voltage coils. The pre-formed reinforcing material has a dense structure like reinforced concrete, so the mechanical strength is greater than that of pure epoxy resin, and it can withstand sudden short-circuit electric power without damage.


product description


Structural modeling: Our company produces three-phase three-column amorphous alloy dry-type transformer, which inherits the advantages of cast-type dry change, with more reasonable structure and more reliable performance.

Low loss: The product no-load loss is equivalent to 40% of SCB10 type products, excellent energy saving effect, economical operation and maintenance-free.

Low noise: The noise level of the product is 10-15 dB lower than the current professional standard JB/T10088-2016 "6-220KV transformer sound level".

Low partial discharge: The resin mixture adopts advanced foreign stirring method and vacuum film degassing technology to make the mixture evenly stirred, completely eliminating the bubbles in the mixture. The product has only a very low partial discharge and can be controlled below 5PC. Both the high and low voltage coils are cast under vacuum and pressure, so that the resin insulation has both full encapsulation and interlayer leaching. The cast body has a dense solidified structure, which is flame retardant, explosion-proof and does not pollute the environment.

The insulating material such as glass fiber wound around the coil has self-extinguishing characteristics, and does not generate an arc due to a short circuit, and the resin does not generate toxic and harmful gas under high heat.

High mechanical strength: The resin with filler makes the difference of expansion coefficient in the casting body small, the curing shrinkage rate is small, the internal stress is small, and the hardness of the cured product is high. It is placed in the epoxy resin encapsulation layer on the inner and outer surfaces of the high and low voltage coils. The pre-formed reinforcing material has a dense structure like reinforced concrete, so the mechanical strength is greater than that of pure epoxy resin, and it can withstand sudden short-circuit electric power without damage.


Product parameters



model

Rated Capacity(KVA

Junction group label

Voltage combination(KV

Load loss(W

Load loss(W120℃(F

No-load current(%

Short circuit resistance(%

high pressure

Tap range

Low pressure

SCH15-30

30

Dyn11

6

6.3

6.6

10

10.5

11

±5%

±2×2.5%

0.4

70

710

1.6

4.0

SCH15-50

50

90

1000

1.4

SCH15-80

80

120

1380

1.3

SCH15-100

100

130

1570

1.2

SCH15-125

125

150

1850

1.1

SCH(B)15-160

160

170

2130

1.1

SCH(B)15-200

200

200

2530

1.0

SCH(B)15-250

250

230

2760

1.0

SCH(B)15-315

315

280

3470

0.9

SCH(B)15-400

400

310

3990

0.8

SCH(B)15-500

500

360

4880

0.8

SCH(B)15-630

630

420

5880

0.7

SCH(B)15-630

630

410

5960

0.7

6.0

SCH(B)15-800

800

480

6960

0.7

SCH(B)15-1000

1000

550

8130

0.6

SCH(B)15-1250

1250

650

9690

0.6

SCH(B)15-1600

1600

760

11730

0.6

SCH(B)15-2000

2000

1000

14450

0.5

SCH(B)15-2500

2500

1200

17170

0.5

SCH(B)15-1600

1600

760

12960

0.6

8.0

SCH(B)15-2000

2000

1000

15960

0.5

SCH(B)15-2500

2500

1200

18890

0.5



Order online

If you are interested in our products, or if we have anything to help you, you can always call our national customer service number:400-110-2022

In order to serve you better and faster, please fill in the relevant information carefully, we will be happy to serve you!

Consultation Service

Thank you for coming to our company's official website. If you are interested in our products, or would like to consult the company related questions, please leave a message for us, we will reply and serve you as soon as possible.

Copyright : Jiangsu Huachen Transformer Co., Ltd.

Design production:wstx.com.cn
w88
XML 地图 | Sitemap 地图